Short answer

Match the battery voltage to the system it powers. 12V runs the DC loads in almost every RV, van and boat and suits small to mid-size inverters. 24V is common for trolling motors and some marine and off-grid systems, and is usually built from two 12V batteries in series. 48V suits large inverters, golf carts and bigger off-grid systems because it moves the same power at a quarter of the current of 12V. Expion360 makes 12V and native 48V LiFePO4 batteries, all with a 12-year warranty.

How do 12V, 24V and 48V systems compare?

12V24V48V
LiFePO4 nominal voltage12.8V25.6V51.2V
Current to deliver 1,200 WAbout 94AAbout 47AAbout 23A
Cable size and voltage dropLargest cable, most dropSmallerSmallest cable, least drop
Typical usesRV and van house power, boat house loads, small to mid-size invertersTrolling motors, some marine and off-grid systemsGolf carts, large inverters, off-grid solar, larger RVs
Runs standard 12V appliances directlyYesNo — needs a converterNo — needs a converter
Expion360 optionFull 12V rangeTwo 12V batteries in seriesNative 48V: 36Ah GC2 and 60Ah EX2 Edge

Current figures ignore inverter losses. Check your battery's spec sheet for series and parallel wiring limits.

How much energy does each Expion360 battery store?

ModelNominal voltageCapacityStored energy
12V 100Ah Group 2712.8V100Ah1,280 Wh
12V 162Ah GC212.8V162Ah2,074 Wh
12V 240Ah EX2 Edge12.8V240Ah3,072 Wh
12V 450Ah EX112.8V450Ah5,760 Wh
48V 36Ah GC251.2V36Ah1,843 Wh
48V 60Ah EX2 Edge51.2V60Ah3,072 Wh
Stored energy = nominal voltage × capacity. Compare batteries of different voltages in watt-hours, not amp-hours.

Why do higher-voltage systems use less current?

Power is voltage times current. To deliver the same 1,200 watts, a 12V system draws roughly four times the current of a 48V system. Lower current means thinner, lighter, cheaper cable, less voltage drop over long runs and less heat at every connection. That is why large inverters and big off-grid systems tend to run at 48V, while smaller RV and marine systems stay at 12V.

Power (W) = Voltage (V) × Current (A)

Should I compare batteries in amp-hours or watt-hours?

Watt-hours, whenever the voltages differ. Amp-hours only compare like with like: a 48V 60Ah battery and a 12V 240Ah battery both store 3,072 Wh, even though one is rated at a quarter of the amp-hours. Multiply nominal voltage by amp-hours to get watt-hours, then compare.

48V 60Ah = 12V 240Ah = 3,072 Wh

Can I build a 24V or 48V system from 12V batteries?

Often, yes: two 12V batteries in series make 24V and four make 48V, as long as the batteries are identical in model, capacity, age and state of charge and the manufacturer allows series wiring. Check the spec sheet for series and parallel limits before you wire. A native 48V battery avoids balancing several 12V batteries against each other and keeps monitoring to one battery.

Match model, capacity, age and state of charge

When does a 48V battery make sense?

When the system is built around 48V equipment: golf carts and utility vehicles, inverter-chargers in the 3,000-watt-plus class, and off-grid solar systems with long cable runs. Expion360 makes two native 48V LiFePO4 batteries, the 48V 36Ah GC2 and the 48V 60Ah EX2 Edge, both with SmartTalk™ Bluetooth and CAN Bus; the EX2 Edge also has VHC™ heating.

48V 36Ah GC2: 38.5 lb48V 60Ah EX2 Edge: VHC™ heated

Do I need a different charger for 24V or 48V?

Yes. The charger, solar controller, inverter-charger and any DC-to-DC charger all have to match the system voltage and have a LiFePO4 profile. If you still need 12V for lights, pumps and fans in a 24V or 48V system, add a DC-to-DC converter to step down to 12V.

UL1973 listed · UL File No. 22D01UL1642-recognized cells12-year warranty

Battery voltage FAQ

Is 48V safer than 12V?
Both are low-voltage DC. 48V runs at lower current for the same power, which means less heat in cables and connections, but it still needs proper fusing, cable sizing and installation.
Can I mix 12V and 48V batteries?
Not in the same battery. Each system voltage needs its own batteries, wired to equipment rated for that voltage.
Does Expion360 make a 24V battery?
Expion360 makes 12V and 48V LiFePO4 batteries. For 24V, two matching 12V batteries are wired in series — check the spec sheet for series limits.
Do 48V Expion360 batteries carry the same warranty?
Yes. Every Expion360 house battery, 12V or 48V, carries the 12-year warranty.
Kevin Formalarie, Expion360

Published October 7, 2026.

Size the system, then the battery.

12V and 48V LiFePO4 batteries for RV, marine, golf and off-grid systems, all with a 12-year warranty.